Congratulations on Gemtree becoming comprehensive fire-rated board supplier for Modular Integrated Construction (MIC) .   
Fire-rating System
For constructions provide periods of fire resistance from 60 to 240 minutes integrity and insulation, and installation details of fire resistance partition, please consult GEMTREE BUILDING PRODUCTS.
2 Hours Insulated Partition System (BS EN 1364-1)

1 layer of 12mm Gemtree 80 boards and Gemtree80 fillets 90×3mm thick fixed to steel framework by M4 self-tapping screws.

小時歐標防火隔熱隔牆系統

1 layer of rock wool 50mm thick with density 80kg/m3 filled in the cavity of partition.

Required Fire Resistance Period

GMS steel channels 0.6mm thick fixed at 610 mm centres vertically. GMS steel channel 0.6mm thick fixed horizontally.

Insulation(minutes)
Insulation(minutes)
Integrity(minutes)
Integrity(minutes)
120
167
Test Result
120
181
NOTES
       
        
     
   
2